(Optional) V2X Function Activation and Manual Control
V2X Function Activation

After activating the V2X function, the Sigen EV DC Charging Module can serve as additional "energy storage" for power station dispatching, providing power to households during off-grid scenarios or discharging alongside other "energy storage" systems.
The device firmware version (SPC110) must support the V2X Discharge Enable function.

1
Bi-directional V2X operation
For first-time use, click Activate V2X Function, then sign the Risk Disclosure Agreement and fill in the basic vehicle information.
2
My Car
The added Electric Vehicle must support the V2X function.
Multiple Electric Vehicles can be added, with one set as the Preferred Vehicle.
Battery Capacity: Enter the Electric Vehicle's actual battery capacity.
Manual Control

The V2X function must be activated before configuring this parameter.
Once set, the Sigen EV DC Charging Module will be forced to discharge, and the system will prioritize this setting.

1
Add Manual Control
Period: Set the discharge duration for the Sigen EV DC Charging Module.
Power: Set the discharge power (range: 0–25).
2
Stop Discharging
Click to stop forced reverse discharging of the Sigen EV DC Charging Module.
Last updated