(Optional) V2X Function Activation and Manual Control

V2X Function Activation

  • After activating the V2X function, the Sigen EV DC Charging Module can serve as additional "energy storage" for power station dispatching, providing power to households during off-grid scenarios or discharging alongside other "energy storage" systems.

  • The device firmware version (SPC110) must support the V2X Discharge Enable function.

No.
Parameter Name
Description

1

Bi-directional V2X operation

For first-time use, click Activate V2X Function, then sign the Risk Disclosure Agreement and fill in the basic vehicle information.

2

My Car

  • The added Electric Vehicle must support the V2X function.

  • Multiple Electric Vehicles can be added, with one set as the Preferred Vehicle.

  • Battery Capacity: Enter the Electric Vehicle's actual battery capacity.

Manual Control

  • The V2X function must be activated before configuring this parameter.

  • Once set, the Sigen EV DC Charging Module will be forced to discharge, and the system will prioritize this setting.

No.
Parameter Name
Description

1

Add Manual Control

  • Period: Set the discharge duration for the Sigen EV DC Charging Module.

  • Power: Set the discharge power (range: 0–25).

2

Stop Discharging

Click to stop forced reverse discharging of the Sigen EV DC Charging Module.

Last updated