Virtual Battery Allocation for Aggregator

This feature is exclusively available in Sweden.
The function enables virtual partitioning of ESS into two independent operational units:
The virtual battery can participate in CheckWatt VPP's frequency regulation services
Remaining capacity continues to be optimized by Sigen algorithm

1
Virtual Battery Allocation for Aggregator
When set to , configurable parameters for the Aggregator-dispatched virtual battery become available.
2
Total Battery Capacity
Total battery capacity of the energy storage system.
3
Virtual Battery Capacity
Configure virtual battery capacity allocated for Aggregator dispatch.
(Virtual Battery Capacity≤Total Battery Capacity)
4
Allocation Ratio for Aggregator
The percentage of virtual battery capacity relative to total battery capacity, quantifying dispatch rights allocation.
5
Inverter Rated Max Active Input Power
Maximum allowable output power of the inverter.
6
Inverter Max Active Input Power
Maximum inverter power during virtual battery charging.
(Inverter Max Active Input Power≤Inverter Rated Max Active Input Power, Inverter Max Active Input Power≥Battery Max Charging Power)
7
Inverter Rated Max Active Output Power
Maximum allowable output power of the inverter.
8
Inverter Max Active Output Power
Set the maximum inverter output power allocated to the Aggregator-dispatched virtual battery.
(Inverter Max Active Output Power≤Inverter Rated Max Active Output Power, Inverter Max Active Output Power≥Battery Rated Max Discharging Power)
9
Battery Rated Max Charging Power
Maximum allowable charging power of the battery.
10
Battery Max Charging Power
Set the maximum inverter output power allocated to the Aggregator-dispatched virtual battery.
(Battery Max Charging Power≤Battery Rated Max Charging Power, Battery Max Charging Power≤Inverter Max Active Input Power)
11
Battery Rated Max Discharging Power
Maximum allowable discharge power of the battery
12
Battery Max Discharging Power
Configure the maximum discharge power limit for the Aggregator-dispatched virtual battery.
(Battery Max Discharging Power≤Battery Rated Max Discharging Power, Battery Max Discharging Power≤Inverter Max Active Output Power)
Virtual Battery Setting
1
Operational Mode
Configure virtual battery operating mode.
2
Charging Cut-off SOC
Terminate charging when battery reaches the preset value (e.g. 80%) to prevent overcharging and extend battery life. The setting shall not exceed the system's charge termination SOC.
3
Discharging Cut-off SOC
Discharge termination activates when battery reaches the preset threshold (e.g. 50%) to prevent over-discharge and maintain battery health. The setting shall not fall below the system's discharge cutoff SOC.
Last updated